Description:

Medical electrical equipment - Part 2-72: Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patients (Adopted ISO 80601-2-72:2015, first edition, 2015-09-01, with Canadian deviations)

Publisher:
Canadian Standards Association / National Standard of Canada

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$70.5
Need Help?

CSA Preface

This is the first edition of CAN/CSA-C22.2 No. 80601-2-72, Medical electrical equipment - Part 2-72: Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patients, which is an adoption, with Canadian deviations, of the identically titled ISO (International Organization for Standardization) Standard 80601-2-72 (first edition, 2015-09-01). It replaces CAN/CSA-Z10651-2:06, Lung ventilators for medical use - Particular requirements for basic safety and essential performance - Part 2: Home care ventilators for ventilator dependent patients (adopted ISO 10651-2:2004). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code.

For brevity, this Standard will be referred to as "CAN/CSA-C22.2 No. 80601-2-72" throughout.

This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:14, Medical electrical equipment - Part 1: General requirements for basic safety and essential performance (adopted IEC 60601-1:2005, including Amendment 1:2012, with Canadian deviations) and CAN/CSA-C22.2 No. 60601-1-11:15, Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment (adopted IEC 60601-1-11:2015, with Canadian deviations).

Scope and object

IEC 60601-1:2005+AMD1:2012, Clause 1 applies, except as follows:

201.1.1 *Scope

IEC 60601-1:2005+AMD1:2012, 1.1 is replaced by:

This part of ISO 80601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of a VENTILATOR in combination with its ACCESSORIES, hereafter referred to as ME EQUIPMENT:

- intended for use in the HOME HEALTHCARE ENVIRONMENT;

- intended for use by a LAY OPERATOR;

- intended for use with PATIENTS who are dependent on mechanical ventilation for their life support.

NOTE 1 Such VENTILATORS can also be used for PATIENTS who are not dependent on ventilatory support.

NOTE 2 In the HOME HEALTHCARE ENVIRONMENT, the power driving the VENTILATOR is often not reliable.

NOTE 3 Such VENTILATORS can also be used in non-critical care applications of professional health care facilities.

This part of ISO 80601 is also applicable to those ACCESSORIES intended by their MANUFACTURER to be connected to a VENTILATOR BREATHING SYSTEM or to a VENTILATOR where the characteristics of those ACCESSORIES can affect the BASIC SAFETY or ESSENTIAL PERFORMANCE of the VENTILATOR.

EXAMPLES Breathing tubes, connectors, water traps, expiratory valve, HUMIDIFIER, BREATHING SYSTEM FILTER, external electrical power source, and DISTRIBUTED ALARM SYSTEM.

If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.

HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this part of ISO 80601 are not covered by specific requirements in this part of ISO 80601 except in IEC 60601-1:2005+AMD1:2012, 7.2.13 and 8.4.1.

NOTE 4 Additional information can be found in IEC 60601-1:2005+AMD1:2012, 4.2.

This part of ISO 80601 is not applicable to continuous positive airway pressure (CPAP) ME EQUIPMENT, high-frequency jet ventilators (HFJVs), and high-frequency oscillatory ventilators (HFOVs)[35].

This part of ISO 80601 does not specify the requirements for cuirass and "iron-lung" VENTILATORS.

This part of ISO 80601 does not specify the requirements for VENTILATORS or ACCESSORIES intended for critical care applications, which are given in ISO 80601-2-12.

This part of ISO 80601 does not specify the requirements for VENTILATORS or ACCESSORIES intended for 2 ? ISO 2015 - All rights reserved anaesthetic applications, which are given in ISO 80601-2-13.

This part of ISO 80601 does not specify the requirements for VENTILATORS or ACCESSORIES intended for emergency and transport which are given in ISO 10651-3.

NOTE 5 In the future, ISO 10651-3 is expected to be harmonized with IEC 60601-1:2005, at which time it will be replaced by ISO 80601-2-xx.

This part of ISO 80601 does not specify the requirements for VENTILATORS or ACCESSORIES intended for home-care ventilatory support equipment (intended only to augment the ventilation of spontaneously breathing PATIENTS), which are given in ISO 10651-6.

NOTE 6 In the future, ISO 10651-6 is expected to be harmonized with IEC 60601-1:2005 and IEC 60601-1-11:2015, at which time it will be replaced by ISO 80601-2-xx.

This part of ISO 80601 does not specify the requirements for obstructive sleep apnoea therapy ME EQUIPMENT, which are given in ISO 80601-2-70.[16]

This part of ISO 80601 is a particular International Standard in the IEC 60601-1 and ISO/IEC 80601 series of standards.

201.1.2 Object

IEC 60601-1:2005+AMD1:2012, 1.2 is replaced by:

The object of this part of ISO 80601 is to establish particular BASIC SAFETY and ESSENTIAL PERFORMANCE requirements for a VENTILATOR, as defined in 201.3.217, and its ACCESSORIES.

NOTE ACCESSORIES are included because the combination of the VENTILATOR and the ACCESSORIES needs to be adequately safe. ACCESSORIES can have a significant impact on the BASIC SAFETY or ESSENTIAL PERFORMANCE of a VENTILATOR.


Edition : 1st
File Size : 1 file , 2.4 MB
ISBN(s) : 9781488311383
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 113
Product Code(s) : 2425668, 2425669, 2425668
Published : 06/30/2017

History


Related products

CAN/CSA C22.2 NO. 60601-2-29-10 (R2023)
Published Date: 01/01/2010
Medical electrical equipment - Part 2-29: Particular requirements for the basic safety and essential performance of radiotherapy simulators (Adopted IEC 60601-2-29:2008, third edition, 2008-06)
$44.1
CAN/CSA C22.2 NO. 60601-2-41:23
Published Date: 03/28/2023
Medical electrical equipment — Part 2-41: Particular requirements for the basic safety and essential performance of surgical luminaires and luminaires for diagnosis (Adopted IEC 60601-2-41:2021, third edition, 2021-09, with Canadian devbiations)
$126.3
CAN/CSA C22.2 No. 60601-2-49:11 (R2021)
Published Date: 03/29/2012
Medical electrical equipment - Part 2-49: Particular requirements for the basic safety and essential performance of multifunction patient monitoring equipment (Adopted IEC 60601-2-49:2011, second edition, 2011-02)
$75.6

Best-Selling Products

PDI BPSGI
Published Date:
Basic Principles for Sizing Grease Interceptors
PDI G 101
Published Date: 03/01/2010
Testing and Rating Procedure for Hydro Mechanical Grease Interceptors with Appendix of Installation and Maintenance
PDI G 102
Published Date:
Testing and Certification for Grease Interceptors with FOG Sensing and Alarm Devices
PDI GGI-EM
Published Date: 01/01/2010
Guide To Grease Interceptors: Eliminating the Mystery
PDI MGO
Published Date:
Model Grease Ordinance
PDI MSREPFS
Published Date: 01/01/2009
MINIMUMSPACE REQUIREMENTS FOR ENCLOSED PLUMBING FIXTURE SUPPORTS